Gas analyser MAT1400 for O2 measurement

Preis auf Anfrage

Ab Lager lieferbar

Measurement of modified atmosphere with ZrO2 measuring cell;
Oxygen: 0–100Vol.-%

The MAT1400’s zirconium dioxide sensor (ZrO2) measures the oxygen concentration in the entire measurement range from 0-100 vol%. Especially at very low concentrations, it achieves an outstanding accuracy of ±0.02 Vol.-%. This makes the MAT1400 equally suitable for testing oxygen-free and oxygen-rich modified atmospheres. It can also be used in cold rooms from an ambient temperature of 10°C (non-condensing).

Basic functions

  • Easy and intuitive to operate via touchscreen – even for untrained personnel
  • Drift-free zirconium dioxide sensor (ZrO2) measures in the measurement range range of 0-100Vol.-%
  • Short measurement period
  • Only a small sample volume required
  • Various interfaces for the convenient transfer of measured values (USB, Ethernet, RS-232)
  • Any number of measurement methods for monitoring the measurement process by method, batch, product and/or production line, including limit value monitoring
  • GMP-compliant analysis with a high standard of user management, self-analysis of the device and alarm limit and method settings
  • Also suitable for continuous gas mixture monitoring

Highlights

You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.

More Information

Technical data

Spezifikation Gasanalysator MAT1400 Modell
Durchschnittliche Messzeit 1) 5 Sekunden
Minimales Kopfraumvolumen 2) 5ml
Aufheizzeit 10 Minuten
Justierung Automatisch (menügeführt)
Skalen Sauerstoff
Methoden & Benutzer Über 10000 möglich
Geräte Basisdaten
Bedienung 7.0’’ kapazitiver Touchscreen, 800 x 480 Pixel Touchscreen, Tastatur, Maus, Barcodescanner
Schnittstellen 1x USB, 1x RS-232, 1x Ethernet, LIMS
Maße (B x H x T) 200 mm x 150 mm x 350 mm
Gewicht 4,6 kg
Zusätzliche Funktionen Eingabe von Produkt- und Chargenbezeichnungen, Alarmgrenzenverwaltung, Benutzerverwaltung,
Messwertstabilisierung, Luftdruckanzeige
Temperaturdaten
Umgebungstemperatur 10-50° C
Feuchtigkeit Messgas <90% rF (nicht kondensierend)
Elektrische Kenndaten
Betriebsspannung 100-250 VAC
Leistungsaufnahme max. 60 W
Bemessungsfrequenz 50/60 Hz
1) nach Aufheizzeit, 2) nach Vorspülen
Analysedaten Sauerstoff (O2)
Messbereich 0-100 Vol.-%
Sensorgenauigkeit / 1 ±0,02 Vol.-% abs. (< 1 Vol.-%)
Sensorgenauigkeit / 2 ±3 Vol.-% rel. (> 1 Vol.-%)
Auflösung 0,001 Vol.-%
O2-Sensor Daten
Typ Zirconiumdioxid-Sensor (ZrO2)
Drift Driftfrei
Querempfindlichkeit Querempfindlichkeit gegenüber brennbaren Gasen

Sensor

At the heart of the gas analysers is the sensor technology
Various models with different sensor technology are optionally available for optimum adaptation to the respective application. The respective proven sensor technology should be selected for each specific application and process. The range of sensors available allows optimum adaptation in terms of measurement range and accuracy:

  • Electrochemical cell (EC) for O2 measurement
  • Zirconium dioxide cell (ZrO2) for O2 measurement
  • Non-dispersive infrared sensor (NDIR) for CO2 measurement

The following overview provides an initial overview. We will be happy to discuss which device models are suitable for your specific requirements in a personal consultation.

Please feel free to contact us

Gasanalysator MAT1100-Modell MAT1200-Modell MAT 1400-Modell MAT1500-Modell
Einsatzgebiet Sporadische O2-Stichprobenkontrolle Kombinierte O2- und CO2-Messung Hohes Probenaufkommen oder hohe O2-Konzentration Hohes Probenaufkommen oder hohe O2-Konzentration + Kombinierte O2/CO2-Messung
Vorteil Modellvariante Wirtschaftliche Variante, schnelle Einsatzbereitschaft, driftarm Wirtschaftliche Variante, driftarm, umweltkompensierte CO2-Messung Hohe Lebensdauer, schnelle Messung, hohe Präzision bei geringsten O2-Konzentrationen, weiter Messbereich, driftfrei Hohe Lebensdauer, schnelle Messung, hohe Präzision bei geringsten O2-Konzentrationen, weiter Messbereich, ZrO2: driftfrei, NDIR: driftfrei, umweltkompensierte CO2-Messung
O2-Sensortechnik Elektrochemische Sauerstoffzelle (EC) Elektrochemische Sauerstoffzelle (EC) Zirconiumdioxid-Sensor (ZrO2) Zirconiumdioxid-Sensor (ZrO2)
CO2- Sensortechnik – – – Nichtdispersive Infrarotsensor (NIR) – – – Nichtdispersiver Infrarotsensor (NIR)
N2-Sensortechnik – – – Arithmetische Ermittlung – – – Arithmetische Ermittlung