Density meters fully automatic sample supply
17.415,00 € – 18.920,00 €
excl. VAT
+ Shipping costs
Ab Lager lieferbar
Enables high sample throughput and offers increased productivity.
These digital density meters for fully automatic sample supply work with the proven oscillating U-tube technology. These density meters are ideal for working environments involving a high sample throughput that require fully automated handling of the entire process, from sample supply to cleaning and drying. Both the AS80 or AS90 autosamplers in combination with the DS7070 peristaltic pump are included in the set, thus enabling the automated measurement of up to 89 samples. The minimum sample volume supply of the oscillating U-tube is less than 1 ml. The internal Peltier temperature control ensures a fast and stable sample temperature. Whether density, relative density, Brix, alcohol, sulphuric acid concentration or other user-configured scales, the configuration options are virtually unlimited. Due to the chemical-resistant sample-carrying parts made of borosilicate glass and PTFE, these instruments are suitable for low to slightly viscous, aggressive samples. They are used in various branches of the pharmaceutical, chemical, petrochemical, and food and beverage industries. They can be used to determine quality or purity and to measure concentration in binary mixtures.
Basic function
- Fully automatic sample supply, cleaning & drying
- Suitable for automatic, semi-automatic and manual sample supply
- Individual measurement methods and cleaning procedures as well as sampler templates possible
- Intuitive Operation via 7.0″ touch-screen display, 6 languages selectable
- Easy to understand, menu-guided adjustment
- Scales such as density, relative density, Brix, alcohol and sulphuric acid concentration are pre-installed; further scales can easily be set up
- Integrated rinsing port and optional separate version
- Conformity with GMP/GLP, 21 CFR Part 11, pharmacopoeias (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST
Highlights
You are currently viewing a placeholder content from YouTube. To access the actual content, click the button below. Please note that doing so will share data with third-party providers.
More InformationTechnical data
| Spezifikation | Dichtemessgeräte DS7000-Serie |
|---|---|
| Messbereich | 0–3 g/cm³ |
| Temperierbereich | 10–40 °C |
| Messgenauigkeit 1) |
DS7700: ±0,001 g/cm³ DS7800: ±0,0001 g/cm³ |
| Temperiergenauigkeit | ±0,01 °C |
| Skalen |
Dichte (g/cm³), Relative Dichte,
Benutzerdefiniert (unbegrenzt), Brix
(%Brix), Alkoholkonzentration (Vol.- %), Schwefelsäurekonzentration (Gew.-%) |
| Auflösung |
DS7700: 0,001 g/cm³ DS7800: 0,0001 g/cm³ |
| Messzeit 2) | 3 Sekunden |
|
Minimales Probenvolumen |
0,9 ml |
| Druckbereich (relativ) | 0–9 bar |
| Temperaturmessgenauigkeit | ±0,02 °C |
| Temperaturmessauflösung | 0,01 °C |
| Methoden & Benutzer | Über 10000 Methoden möglich |
| Justierung |
Automatisch (menügeführt) Luftdrucksensor für Justierung Temperierte Kalibriermittel |
| Probenberührende Teile | Borosilikatglas, PTFE; (ermöglicht Messung von nahezu allen Flüssigkeiten, Emulsionen & Pasten) |
| Zusätzliche Funktionen |
Audit Trail Benutzerverwaltung Messwertstabilisierung Luftdruckanzeige |
| Bedienung |
7.0” – kapazitiver Touchscreen, 800 x 480 Pixel, abwischbar Touchscreen, Tastatur, Maus und/oder Barcodescanner |
| Schnittstellen | 1x USB, 1x RS-232, 1x Ethernet, LIMS |
| Maße (B x H x T) | 220 mm x 220 mm x 430 mm |
| Gewicht | 5,3 kg |
| Betriebsspannung | 100–240 V, 47–63 Hz |
| Leistungsaufnahme (Messbetrieb) | 25 W |
| Leistungsaufnahme (max.) | 120 W |
¹)Under normal conditions for density measurement (20 °C, 1013 hPa, 50 % relative humidity)
²) After temperature equalization
Documents
| Title | Download |
|---|---|
| Brochure Density Meters | DownloadPreview |
Calibration standards
-
Standard density measurement Isooctane
217,00 €Certified Calibration standard for density measurement. Reference value at 20°C: 0.6900 g/cm³
-
Density standard n-Nonan
217,00 €Certified Calibration standard for density measurement. Reference value at 20°C: 0.7200 g/cm³
-
Standard density measurement Ultrapure Water
217,00 €Certified Calibration standard for density measurement. Reference value at 20°C: 0.9882 g/cm³
-
Standard density measurement Dichlorotoluene
217,00 €Certified Calibration standard for density measurement. Reference value at 20°C: 1.2500 g/cm³
Consumables
-
Tube set TPE/Olive for DS7070
25,00 €TPE pump hoses and PTFE hose connections (olive) for peristaltic pump
-
Accessories
-
-
-
Transparent protective cover
49,00 €Protective cover for KRÜSS devices: DR6000, DS7000, MAT1000 series and M5000
-
Olive/UNFa density meter adaptor
12,00 €Adaptor for connecting the Tygon hoses to the UNF on the density meter
-
Adaptor density meters UNFi/Luer
22,00 €Adaptor for connecting the PTFE hose to the Luer on the density meter
-
-
Printer CBM910
380,00 €Matrix printer suitable for many KRÜSS laboratory devices, e.g: DR7000 series, M5000, M3000, P9000 series, FP8000 series
-
Interface cable for printer (CBM910)
23,00 €Interface cable for connecting CBM910 to KRÜSS devices, such as: DR7000 series, P9000 series, FP8000 series
-
-
Ink ribbon for printer (CBM910)
13,00 €Ink ribbon as replacement for CBM910 printer, for printing measurement results